    Introducing the Masimo Pronto-7T - for easy-to-use spot-check testing of haemoglobin, SpO2, pulse rate, and perfusion index.

    Challenges with Traditional Haemoglobin Testing

    Haemoglobin is one of the most commonly ordered tests in both hospital and non-hospital settings because it is critical to assessing anaemia and blood loss. However, traditional invasive lab testing provides delayed results and requires a painful needle stick and time-consuming blood draws.

    A New Solution for Haemoglobin Testing

    Noninvasive, immediate, and accurate spot-check testing with the Masimo Pronto-7 offers the following benefits:

    Clinician

    • Facilitates timely diagnosis and treatment decisions
    • Reduces need to wait for lab results

    Staff

    • Easy to use - reduces training time and improves efficiency
    • Decreases risk of accidental needle sticks and exposure to blood-borne pathogens
    • Requires no lab consumables or waste disposal

    Patient

    • Prevents painful needle sticks and time-consuming blood draws
    • Enables immediate face-to face counseling with clinician

    PERFORMANCE

    Measurement Range

    SpO2. . . . . . . . . . . . . . . . . . . . . . . . . . 0-100%
    PR (pulse rate). . . . . . . . . . . . . . . . . . . . . . . . 30-250 bpm
    SpHb (total haemoglobin). . . . . . . 0-25 g/dL
    PI (perfusion index). . . . . . . . . . . 0.02%-20%
    Accuracy
    Arterial Oxygen Saturation, 70% to 100% . . . . ± 2%
    Pulse Rate Accuracy. . . . . . . . ± 3 bpm
    Total Haemoglobin Concentration Accuracy (SpHb g/dL). . . . 6-18 g/dL ± 1 g/dL
    Resolution
    Arterial Oxygen Saturation (SpO2) . . . . . . 1%
    Pulse Rate. . . . . . . . . . . . . . . . . . . . . 1 bpm
    Total Haemoglobin. . . . . . . . . . . . . . . 0.1 g/dL
    Perfusion Index. . . . . . . . . . . . . . . . . . . . 0.01%

    Specifications

    Product
    Mode of operation . . Spot check
    Test time. . . . . . . 45 seconds
    Test storage capacity. . . . . . . . . . . . . . . . . . . . . 8,000
    Wireless connectivity. . . . . . . . . . . . . . . . . . . . . .802.11 b/g, Bluetooth
    Reporting modes. . Print, email, audible
    Report formats. . . . . . . Single test, multiple test, device summary
    Reporting devices . . . . . Optional Bluetooth thermal printer, USB, 802.11
    wireless (PCL 5, 5e, 6), or Bluetooth printing to validated printers
    Electrical
    Battery power. . . . . . . . . . . . . . Rechargeable lithium polymer
    Capacity . . . Approximately 2 hours after full charge
    Number of spot checks on fully charged battery . . . . . . . . . . . . 140
    Battery charging time. . . . . . . . . . . . . . . . . . . 5 hours
    when powered off
    6 hours when powered on
    Isolation . . . . . . . . . . . . . . . . . . . . . . . . Medical
    grade AC/DC adapter
    AC power . . . . . . . . . . . . . . . . . . . 100-240V, 50-60 Hz, 15VA max
    Environmental
    Operating temperature . . . . . . . . . . . 41 °F to 104 °F (5 °C to +40 °C)
    Storage temperature . . . . . . . -40 °F to 158 °F (-40 °C to +70 °C)
    Operating humidity. . . . 5% to 95% non-condensing
    Operating altitude. . . . . . 500 mbar to 1060 mbar pressure -1000 ft to 18,000 ft (-304 m to 5,486 m)
    Physical Characteristics
    Dimensions . . . . 5.1” x 2.8” x 1” (13 cm x 7.2 cm x 2.5 cm)
    Weight . . . . . . . . . . . . . . 10.5 oz (296.4 g)
    Visual alarms . . . . . . . . . . . . . . . . . . . . . . . . Low battery, system failure
    Display/Indicators
    Data display. . . . SpO2%, pulse rate (PR) beats per minute, SpHb g/dL, PI%,
    battery level indicator, pulse plethysmograph waveform
    Type . . . . . . . . . . . . . . . . . . . . . . . . . 3.7” resistive touchscreen
    Compliance
    EMC compliance. . . . . . . . . . . . . . . . . . . . . . . . .EN60601-1-2, Class B
    Equipment classification . . . . . . . . . . . . . . . . . . . . IEC 60601-1
    Type of protection (battery power) . . . . . . . . . . . . . .Internally powered
    Type of protection (AC power) . . . . . . . . Class 2
    Degree of protection-sensor . . . . . . . . . . . . . . . Type BF-applied part